plc automation

Hotline

Pepperl & Fuchs/P+F/Pepperl+Fuchs KFU8-DW-1.D Speed Moni

description:Rotation Speed Monitor; Monitoring Up To 40 kHz; 4 Digit LED Display; 190149 Rotation Speed Monitor; Monitoring Up To 40 kHz; 4 Digit LED Display; 190149 ...
BASIC INFO
Pepperl & Fuchs/P+F/Pepperl+Fuchs KFU8-DW-1.D Speed Monitor/isolated barrier KFU8-DW-1.D Rotation Speed Monitor;Monitoring Up To 40 kHz; 4 Digit LED Display;190149  With Good Price

Rotation Speed Monitor KFU8-DW-1.D
Pepperl+Fuchs isolated barrier KFU8-DW-1.D



1.  Technical Specifications
Physical
Mount DIN Rail
Compliance
Ratings IP20
RoHS Compliant

2.  Descriptions

Rotation Speed Monitor; Monitoring Up To 40 kHz; 4 Digit LED Display; 190149 
Allied Electronics & Automation
Monitoring relays speed 
Distrelec
P+F Control Equipment 
Steven Engineering
Control Equipment 
Newark
 
 
3.    Rotation Speed Monitor KFU8-DW-1.D

Pepperl & Fuchs/P+F/Pepperl+Fuchs KFU8-DW-1.D Speed Monitor/isolated barrier KFU8-DW-1.D Rotation Speed Monitor;Monitoring Up To 40 kHz; 4 Digit LED Display;190149  With Good Price
  • Speed monitoring up to 40 kHz
  • 1 pre-select value with relay output and LED indicator
  • 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable
  • Start-up delay
  • Menu driven operation via 4 front keys
  • Period measurement
  • Output signal can be inverted
  • Display devices can be set between 0.1 ... 2.5 sec.
 
4. Product Details:

Product Description
Rotation Speed Monitor
General specifications
Signal type Digital Input
Functional safety related parameters
MTTFd 100 a
Supply
Rated voltage 200 ... 230 V AC ; 100 … 130 V AC; 50/60 Hz 
20 VDC ... 30 VDC
Fusing external fusing 4 A
Power consumption AC: < 5 VA
DC: < 5 W
Input
Connection side field side
Input 1
Connection terminals 8-, 9+
Connectable sensor types NAMUR sensors according to DIN EN 60947-5-6
Open loop voltage 8.2 V DC
Short-circuit current 6.5 mA
Switching point 1.2 ... 2.1 mA Switching hysteresis approx. 0.2 mA
Input frequency 0.002 ... 10000 Hz, pulse length/duration: ≥ 20µs
Impedance 1.2 kΩ
Input 2
Switching point high: 16 ... 30 V DC; max.10 mA due to integrated constant current sink; R≅ 3 kΩ
low: 0 ... 6 V DC
Input frequency 0.002 ... 40000 Hz, pulse length/duration: ≥ 12µs
Connection terminals 7+, 13- sensor supply
terminals 14, 15 NPN/PNP input (galvanically isolated)
Connectable sensor types Two, three, or four-wire proximity switch, incremental rotary encoder, or externally generated pulses 16 ... 30 V
Sensor supply 19 ... 28 V DC non-stabilised; ≤ 30 mA short-circuit protected
Input 3
Start-up override Triggering by external signal 16 ... 30 V or Place jumper between terminals 2/3 or by switching on supply voltage (terminal 2 and terminal 3 permanently bridged)
Jumpering time 0.1 ... 999.9 s (External trigger signal)
Output
Connection side control side
Relay 1 changeover contact 
NO, NC, COM
Sensor supply 24 V DC ± 10 %, 30 mA , short-circuit protected
Contact loading 250 V AC/2 A/ cos φ ≥ 0.7
40 V DC/2 A
Delay ≤ 20 ms (incl. calculation time)
Mechanical life ≥ 30.000.000 switching cycles
Transfer characteristics
Changing interval 5 ms (Internal processing time)
Time delay before availability ≤ 400 ms
Measuring error 0 ... 40000 Hz: ≤ ±0,10% 
Display: ±1 digit
Timer function ON-delay, OFF-delay, one shot, pulse extension
Time 0 ... 999.9 s ; mode of operation reversible
Indicators/settings
Display elements display , 4-digit, 7-segment red display, 7 mm digit height and LED
LED indication yellow LED : switching state
Display indication 0.002 ... 9999 Hz or 
0,01 ... 9999 min-1
Control elements Control panel
Configuration via operating buttons
Labeling space for labeling at the front
Standard conformity
Electromagnetic compatibility acc. to EN 50081-2 / EN 50082-2
Ambient conditions
Ambient temperature -25 ... 40 °C (-13 ... 104 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Relative humidity max. 80 %, not condensing
Altitude 0 ... 2000 m
Operating conditions The device has only to be used in an indoor area.
Mechanical specifications
Connection assembly Caution: Please be aware that the device may only be connected to a switchable power supply. The switch or circuit breaker must be easy to reach and identified as the separator for the device.
Degree of protection IP20
Connection coded, removable terminals , max. core cross section 0.34 ... 2.5 mm2
Construction type modular terminal housing in Makrolon, System KF 
For use in the switch cabinet/switch cabinet module
Mounting snap-on to 35 mm standard rail or screw fixing

5. Other Pepperl+Fuchs Models:

 Pepperl & Fuchs/P+F/Pepperl+Fuchs KFU8-DW-1.D Speed Monitor/isolated barrier KFU8-DW-1.D Rotation Speed Monitor;Monitoring Up To 40 kHz; 4 Digit LED Display;190149  With Good Price

KFD2-SR2-Ex2.W
KFD2-SL2-Ex1
KFD2-SR2-Ex1.W
KFD2-STC4-Ex1
KFD2-SR2-EX.1.W.LB
KFD2-EB2.R4A.B
KFD2-SCD2-EX1.LK
KFD2-SR2-EX2.W
KFD2-SL2-EX2.B
KFD0-TT-EX1
KFD0-TR-EX1
KFD2-STC4-EX2
KFD2-UFC-EX1.D
KFD2-SCD2-EX2-LK
KFD2-CD-EX1.32-15
KFD2-STC4-EX1.2O
KFD2-SH-EX1.T.OP
KFD2-SR2-EX2.2S
KFD2-BR-1.PA.93
KFD2-UT2-EX2
KFD2-UFC-EX1.D
KFD0-SD2-EX1.1045
KFD2-SOT2-EX1.LB
KFD2-STC4-EX1.20
KFD2-STC4-1.20
KFD2-SCD2-EX2.LK
KFD2-SCD2-2.LK
KFD2-SH-EX1
KFD0-SD2-Ex2.1245
KFD2-SL2-Ex1.LK
KFD2-BR-Ex1.3PA.93
KFD2-CD2-EX2
KFD2-UT2-EX2
KFD2-STC4-EX1.2O
KFD2-CR4-1.2O
KFD2-CD2-EX1
KFD2-SL2-EX2
KLD2-PR-1.IEC
KFD2-WAC2-EX1.D
KFD2-UFT-EX2.D
KFD2-UFC-1.D
KFD-STC4-EX1.2O.DE
KFD2-SCD2-EX1
KFD2-PT2-Ex1
KFD2-SR2-EX2.2S
KFD0-SD2-EX1.1045
KCD2-E2L 
KCD2-STC-EX1
KFD2-SR2-EX1.W
KFD2-SCD2-EX1-LK
KCD2-SCD-EX1
KFD2-UT2-EX1
KFD2-VR4-EX1.26
KFD2-SR2-EX1.W.LB
KFDO-RSH-1
KFD2-GS-1.2W 
KFD2-EB.R4A.B
KFD0-SCS-EX1.55
KFD2-EX1.32
KFD2-STC4-Ex1-Y1.
KFD2-SR2-EX2.2S
KFD2-SCD2-EX2.LK
KFA5-SR2-EX1.W.LB
KFD2-RR-EX1
KFD2-SCD-EX1.LK
KFA6-STR-1.24.500
Z787.H
KFD0-CS-EX2.50P
KFD0-CS-EX2.51P
KFA6-SR2-EX1.W.LB
KFA5-SR2-EX1.W
KFD2-ST2-EX2
KFD2-DWB-1.D
KFD2-UT-EX1
KFD2-SR2-2.2S
HD2-FBPS-1.500
HD2-DM-B
KFD2-GU-Ex1.D
KFD2-PT2-EX1-5
KFD2-DWB-Ex1.D
KFA6-DWB-EX1.D
KFD2-STV4-EX2-2
Z728
Z828
KFD0-CS-Ex1.54P
KFU8-DW-1.D
KFD0-RO-Ex2
S1SD-1TI-1U
KFD2-GUT-1.D
KFD0-SCS-1.55
KFD2-DWB-Ex1.D
KFD2-PT2-EX1-5
KFA6-DWB-EX1.D
KFD2-STV4-EX2-2
Z728
Z828
KFD0-CS-Ex1.54P
KFD0-RO-Ex2
KFD2-GUT-1.D
KFD2-SCD2-1.LK
KFD2-GU-Ex1

6. Quality assurance:
 
100% original product, 100% quality assurance. 
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex and EMS, the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 

7.Contact details:

HONGKONG XIEYUAN TECH CO., LIMITED

Email/Skype:sales5@hkxytech.com/amy@whxyauto.com

Whatsapp/Mobile::+8613135657923
 
Web:www.hkxytech.com/www.plcs-automation.com
 
We mainly supply YOKOGAWA, SIEMENS, EMERSON, ABB, HONEYWELL, Allen Bradley,ENDRESS+ HAUSER, PEPPERL+FUCHS, FESTO, PARKER, FLUKE, WEIDMULLER, MTL, SMC,Schneider, Hirschmann,  ADVANTECH,MOXA, US Sensor, Mean Well, Murphy, YTC. Fisher, Auma, Rittal brands products. 
 
Any brand products inquiry, feel free to contact me.

 
 
 
Pre:PEPPERL+FUCHS Switch Amplifier KFD2-SR2-Ex2.W 132960 Next:Pepperl+Fuchs Pepperl&Fuchs P+F KFU8-UFC-Ex1.D 231197 Fr