Yokogawa differential pressure transmitter/4-20ma pressure transmitter/china pressure transmitter EJA-110E Series



1. SPAN AND RANGE LIMITS:
 
eja110e unit
 
2. MODEL AND SUFFIX CODES:

Yokogawa differential pressure transmitter/4-20ma pressure transmitter/china pressure transmitter EJA-110E Series

Model Suffix Codes Description

EJA110E . . . . . . . . . . . . . . . . . . . . . Differential pressure transmitter
Output signal
-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-J . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)*1
Digital communication (FOUNDATION Fieldbus protocol, refer to
GS 01C31T02-01EN)
Digital communication (PROFIBUS PA protocol, refer to
GS 01C31T04-01EN)
Low Power, 1 to 5 V DC with digital communication (HART 7 protocol)
Measurement
span (capsule)
F . . . . . . . . . . . . . . . . . . . . . . . . . . .
L . . . . . . . . . . . . . . . . . . . . . . . . . . .
M . . . . . . . . . . . . . . . . . . . . . . . . . . .
H . . . . . . . . . . . . . . . . . . . . . . . . . . .
V . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.5 to 5 kPa (2.0 to 20 inH2O) (For Wetted parts material code S)
0.5 to 10 kPa (2.0 to 40 inH2O)
(For Wetted parts material code M, H, T, A, D, B and W)
1 to 100 kPa (4 to 400 inH2O)
5 to 500 kPa (20 to 2000 inH2O)
0.14 to 14 MPa (20 to 2000 psi)
Wetted parts
material *2
. . . . . . . . . . . . . . . . . . . . . . . . . Refer to “Wetted Parts Material” Table.
Process connections
See the table in the next
page for the codes for a
diaphragm seal system.

0 . . . . . . . . . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . . . . . . . . . .
4 . . . . . . . . . . . . . . . . . . . . . .
5 . . . . . . . . . . . . . . . . . . . . . .
without process connector (Rc1/4 female on the cover flanges)
with Rc1/4 female process connector
with Rc1/2 female process connector
with 1/4 NPT female process connector
with 1/2 NPT female process connector
without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts materia J . . . . . . . . . . . . . . . . . . .
G . . . . . . . . . . . . . . . . . . .
C . . . . . . . . . . . . . . . . . . .
B7 carbon steel
316L SST
660 SST
Installation

-7 . . . . . . . . . . . . . . . . .
-8 . . . . . . . . . . . . . . . . .
-9 . . . . . . . . . . . . . . . . .
-B . . . . . . . . . . . . . . . . .
-U . . . . . . . . . . . . . . . . .
Vertical piping, left side high pressure, and process connection downside
Horizontal piping and right side high pressure
Horizontal piping and left side high pressure
Bottom Process Connection, left side high pressure*3
Universal flange*3
Amplifier housing 1 . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . .
Cast aluminum alloy
Cast aluminum alloy with corrosion resistance properties*5
ASTM CF-8M stainless steel*6
Electrical connection

0 . . . . . . . . . . .
2 . . . . . . . . . . .
4 . . . . . . . . . . .
5 . . . . . . . . . . .
7 . . . . . . . . . . .
9 . . . . . . . . . . .
A . . . . . . . . . . .
C . . . . . . . . . . .
D . . . . . . . . . . .
G1/2 female, one electrical connection without blind plugs
1/2 NPT female, two electrical connections without blind plugs
M20 female, two electrical connections without blind plugs
G1/2 female, two electrical connections and a blind plug*7
1/2 NPT female, two electrical connections and a blind plug*7
M20 female, two electrical connections and a blind plug*7
G1/2 female, two electrical connections and a SUS316 blind plug
1/2 NPT female, two electrical connections and a SUS316 blind plug
M20 female, two electrical connections and a SUS316 blind plug
Integral indicator

D . . . . . . . .
E . . . . . . . .
N . . . . . . . .
Digital indicator*8
Digital indicator with the range setting switch (push button)*9
None
Mounting bracket ► B . . . . . .
D . . . . . .
J . . . . . .
K . . . . . .
M . . . . . .
N . . . . . .
304 SST 2-inch pipe mounting, flat type (for horizontal piping)
304 SST or SCS13A 2-inch pipe mounting, L type (for vertical piping)
316 SST 2-inch pipe mounting, flat type (for horizontal piping)
316 SST or SCS14A 2-inch pipe mounting, L type (for vertical piping)
316 SST or SCS14A 2-inch pipe mounting (for bottom process connection type)
None
Optional Codes ¨/ Optional specification

Yokogawa differential pressure transmitter/4-20ma pressure transmitter/china pressure transmitter EJA-110E Series

3. Quality assurance:

1. 100% original product, 100% quality assurance. 
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex and EMS, the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.

Yokogawa differential pressure transmitter/4-20ma pressure transmitter/china pressure transmitter EJA-110E Series

4.Contact details:


HONGKONG XIEYUAN TECH CO., LIMITED


Email/Skype:sales5@hkxytech.com/amy@whxyauto.com


Whatsapp/Mobile::+8613135657923

Web:www.hkxytech.com/www.plcs-automation.com

 

We mainly supply YOKOGAWA, SIEMENS, EMERSON, ABB, Hesman

ROCKWELL, HONEYWELL, ENDRESS+ HAUSER, PEPPERL+FUCHS, FESTO, PARKER, FLUKE, WEIDMULLER, MTL, SMC,Schneider, Hirschmann, ADVANTECH,MOXA, US Sensor, Mean Well, Murphy, allen Bradley, YTC. Fisher brands products. brand products.

Any brand products inquiry, feel free to contact me.


 
 
Pre:None Next:Yokogawa EJX110A differential pressure transmitter/different