description:SIMATIC S7-300, CONROL MODULE FM 355 C, 4 CHANNELS, CONTIN. 4 AI + 8 DI + 4 AO INCL. MULTI-LANG CONFIG. PACK., MANUAL AND GETTING STARTED (GER/EN/FR/IT) ON CD-ROM...
BASIC INFO

6ES7355-0VH10-0AE0

6ES7355-0VH10-0AE0

SIMATIC S7-300, CONROL MODULE FM 355 C, 4 CHANNELS, CONTIN. 4 AI + 8 DI + 4 AO INCL. MULTI-LANG CONFIG. PACK., MANUAL AND GETTING STARTED (GER/EN/FR/IT) ON CD-ROM
 

Supply voltage
Load voltage L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 20.4 V
● permissible range, upper limit (DC) 28.8 V
Input current
from load voltage L+ (without load), max. 310 mA; Typ. 260 mA
from backplane bus 5 V DC, max. 75 mA; typ. 50 mA
Power loss
Power loss, typ. 6.5 W
Power loss, max. 7.8 W
Digital inputs
Number of digital inputs 8
Input characteristic curve in accordance with IEC 61131, type 2 Yes
Input voltage
● Rated value (DC) 24 V
● for signal "0" -3 to +5V
● for signal "1" 13 to 30V
Input current
● for signal "1", typ. 7 mA
Cable length
● shielded, max. 1 000 m
● unshielded, max. 600 m
Analog inputs
Number of analog inputs 4
permissible input voltage for voltage input (destruction limit), max. 30 V
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
● Voltage Yes
● Current Yes
● Thermocouple Yes
● Resistance thermometer Yes
Input ranges (rated values), voltages
● 0 to +10 V Yes
● Input resistance (0 to 10 V) 100 kΩ
● -1.75 V to +11.75 V Yes
● Input resistance (-1.75 V to +11.75 V) 100 kΩ
● -80 mV to +80 mV Yes
● Input resistance (-80 mV to +80 mV) 10 MΩ
Input ranges (rated values), currents
● 0 to 20 mA Yes
● Input resistance (0 to 20 mA) 50 Ω
● 0 to 23.5 mA Yes
● Input resistance (0 to 23.5 mA) 50 kΩ
● -3.5 mA to +23.5 mA Yes
● Input resistance (-3.5 mA to +23.5 mA) 50 Ω
● 4 mA to 20 mA Yes
● Input resistance (4 mA to 20 mA) 50 kΩ
Input ranges (rated values), thermocouples
● Type B Yes
● Input resistance (Type B) 10 MΩ
● Type J Yes
● Input resistance (type J) 10 MΩ
● Type K Yes
● Input resistance (Type K) 10 MΩ
● Type R Yes
● Input resistance (Type R) 10 MΩ
● Type S Yes
● Input resistance (Type S) 10 MΩ
Input ranges (rated values), resistance thermometer
● Pt 100 Yes
● Input resistance (Pt 100) 10 MΩ
Thermocouple (TC)
Temperature compensation
— internal temperature compensation Yes
— external temperature compensation with Pt100 Yes
Characteristic linearization
● parameterizable Yes
— for thermocouples Type B, J, K, R, S
— for resistance thermometer Pt100 (standard)
Cable length
● shielded, max. 200 m; 50 m at 80 mV and thermocouples
Analog outputs
Number of analog outputs 4
Voltage output, short-circuit protection Yes
Voltage output, short-circuit current, max. 25 mA
Current output, no-load voltage, max. 18 V
Output ranges, voltage
● 0 to 10 V Yes
● -10 V to +10 V Yes
Output ranges, current
● 0 to 20 mA Yes
● 4 mA to 20 mA Yes
Connection of actuators
● for voltage output two-wire connection Yes
● for current output two-wire connection Yes
Load impedance (in rated range of output)
● with voltage outputs, min. 1 kΩ
● with voltage outputs, capacitive load, max. 1 µF
● with current outputs, max. 500 Ω
● with current outputs, inductive load, max. 1 mH
Cable length
● shielded, max. 200 m; 50 m at 80 mV and thermocouples
Analog value generation for the inputs
Measurement principle integrating
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 14 bit; 12 bit or 14 bit, parameterizable
● Conversion time (per channel) 16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 Hz and 60 Hz
Analog value generation for the outputs
Settling time
● for resistive load 0.1 ms
● for capacitive load 3.3 ms
● for inductive load 0.5 ms
Encoder
Connection of signal encoders
● for voltage measurement Yes
● for current measurement as 4-wire transducer Yes
Connectable encoders
● 2-wire sensor Yes
— permissible quiescent current (2-wire sensor), max. 1.5 mA
Errors/accuracies
Linearity error (relative to input range), (+/-) 0.05 %
Temperature error (relative to input range), (+/-) 0.005 %/K
Linearity error (relative to output range), (+/-) 0.05 %
Temperature error (relative to output range), (+/-) 0.02 %/K
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-) 0.6 %; +/-0.6 to +/-1%
● Current, relative to input range, (+/-) 0.6 %; +/-0.6 to +/-1%
● Resistance thermometer, relative to input range, (+/-) 0.6 %; +/-0.6 to +/-1%
● Voltage, relative to output range, (+/-) 0.5 %
● Current, relative to output range, (+/-) 0.6 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-) 0.4 %; 80 mV: +/-0.6%; 250 to 1000 mV: +/-0.4%; 2.5 to 10 V: +/-0.6%; 3.2 to 20 mA: +/-0.5%
● Current, relative to input range, (+/-) 0.4 %; +/-0.4 to +/-0.6 %
● Resistance thermometer, relative to input range, (+/-) 0.4 %; +/-0.4 to +/-0.6 %
● Voltage, relative to output range, (+/-) 0.3 %
● Current, relative to output range, (+/-) 0.5 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min. 40 dB
● Common mode interference (USS < 2.5 V) , min. 70 dB
Interrupts/diagnostics/status information
Substitute values connectable Yes; Parameterizable
Integrated Functions
Control technology
● Number of closed-loop controllers 4
Potential separation
Potential separation controller
● between the channels No
● between the channels and backplane bus Yes; Optocoupler
Permissible potential difference
Between the inputs and MANA (UCM) 2.5 V DC
Isolation
Isolation tested with 500 V DC
Connection method
required front connector 2x 20-pin
Dimensions
Width 80 mm
Height 125 mm
Depth 120 mm
Weights
Weight, approx. 470 g