plc automation

Hotline

New & Original Omron CJ1W-SCU41-V1 original cpu module o

description:• Mount a total of up to 16 CPU Bus Units, including these Serial Communications Units, to the CPU Rack or Expansion Racks to create systems with up to 32 serial communications ports.• Connect an NT-AL001 RS-232C/RS-442A Link Adapter t...
BASIC INFO

New & Original Omron CJ1W-SCU41-V1 original cpu module omron cj series plc module Omron CJ1W Communications Unit with good price
CJ1W-SCU41-V1
 
1. Features
 
• Mount a total of up to 16 CPU Bus Units, including these Serial Communications Units, to the CPU Rack or Expansion Racks to create systems with up to 32 serial communications ports.
• Connect an NT-AL001 RS-232C/RS-442A Link Adapter to the RS-232C port to enable 1:N communications.
• With the CJ1W-SCU[]2, you can use a faster baud rate (up to 230.4 kbps) and faster data transfer to the CPU Unit to enable connecting to high-speed external devices.
 
2.  Product Description
 

Item Description
Device name Serial Communications Unit
Classification CPU Bus Unit
Model number CJ1W-SCU22 CJ1W-SCU32 CJ1W-SCU42 CJ1W-SCU21-V1 CJ1W-SCU31-V1 CJ1W-SCU41-V1
Serial
ports
Port 1 RS-232C RS-422A/485 RS-422A/485 RS-232C RS-422A/485 RS-422A/485
Port 2 RS-232C RS-422A/485 RS-232C RS-232C RS-422A/485 RS-232C
Protocol Port 1 Host Link, protocol macro, Serial Gateway, No-
protocol, NT Link, Modbus-RTU Slave, loopback
test , or 1:1 Host Link can be selected for each
port. *1, *2
Host Link, protocol macro, NT Link, or loopback test can be
selected for each port.
Unit Ver. 1.2 or later also supports Serial Gateway, no-
protocol, and 1:1 Host Link modes. (Note: The Serial Gateway
can also be executed in protocol macro mode.) *1
Unit Ver. 1.3 or later also supports Modbus-RTU slave mode.
Port 2

 
New & Original Omron CJ1W-SCU41-V1 original cpu module omron cj series plc module Omron CJ1W Communications Unit with good price
 
3. International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.
Unit
type
Product
name
Specifications No. of
unit
numbers
allocated
Current
consump-
tion (A)
Model Stand-
ards
Commu-
nications
Interface
Communications
functions
5V 24V
CJ1
CPU
Bus
Units
Serial
Communi-
cations Units
(High-speed
type)
2 RS-232C
ports
The following functions
can be selected for each
port with an CJ-system:
Protocol macro
Host Link
NT Links (1:N mode)
Serial Gateway
No-protocol *3
Modbus-RTU Slave
The following functions
can be selected for each
port with an NJ-system:
Protocol macro
Serial Gateway
No-protocol
Modbus-RTU Slave
1 0.28
*1
- CJ1W-SCU22 *2 UC1, N,
L, CE
2 RS-422A/
485 ports
0.4 - CJ1W-SCU32 *2
1 RS-232C
port and
1 RS-422A/
485 port
0.36
*1
- CJ1W-SCU42 *2
CJ1
CPU
Bus
Units
Serial
Communi-
cations Units
2 RS-232C
ports
The following functions
can be selected for each
port:
Protocol macro *4
Host Link
NT Links (1:N mode)
Serial Gateway *5
No-protocol *6
Modbus-RTU Slave *7
1 0.28
*1
- CJ1W-SCU21-V1
*8
UC1, N,
L, CE
2 RS-422A/
485 ports
0.38 - CJ1W-SCU31-V1
*8
1 RS-232C
port and
1 RS-422A/
485 port
0.38
*1
- CJ1W-SCU41-V1
*8

*1. When an NT-AL001 RS-232C/RS-422A Conversion Unit is used, this value increases by 0.15 A/Unit.
*2. Sinple Backup Function and Interrupt notification function cannot be used with an NJ-system.
*3. A Serial Communications Unit with unit version 2.1 or later, a CPU Unit with unit version 1.03 orlater, and Sysmac
Studio version 1.04 or higher are required to use the SerialRcvNoClear instruction.
*4. You can activate Protocol macro trace function when the CPU Unit is set to the RUN/MONITOR mode. (MONITOR
mode is not available with the NJ-series CPU Units.)
*5. The Serial Gateway function is enabled only for Serial Communications Units of unit version 1.2 and later.
*6. The no-protocol function is enabled only for Serial Communications Units of unit version 1.2 and later (and a CS1/CJ1
CPU Unit of unit version 3.0 or a CJ2 CPU Unit is also required).
*7. The Modbus-RTU Slave function is enabled only for Serial Communications Units of unit version 1.3 and later.
*8. This unit cannot be used, with the Machine Automation Controller NJ-series.
Accessories

Model Accessories Specifications
CJ1W-SCU32 2 Serial Port (RS-422A/485)
Connector
Terminal Block Connector (FMC1.5/5-STF-3.5AU by Phoenix Contact)
CJ1W-SCU42 1 Serial Port (RS-422A/485)
Connector
Terminal Block Connector (FMC1.5/5-STF-3.5AU by Phoenix Contact)

Note: A serial port (RS-232C) connector is not provided. Purchase a connector separately for serial port connection.
Plug : XM3A-0921 (manufactured by OMRON) or equivalent
Hood : XM2S-0911-E (manufactured by OMRON) or equivalent
 
New & Original Omron CJ1W-SCU41-V1 original cpu module omron cj series plc module Omron CJ1W Communications Unit with good price
 
4. Quality assurance:
 
100% original product, 100% quality assurance. 
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex and EMS, the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 

5.Contact details:

HONGKONG XIEYUAN TECH CO., LIMITED

Email/Skype:sales5@hkxytech.com/amy@whxyauto.com

Whatsapp/Mobile::+8613135657923
 
Web:www.hkxytech.com/www.plcs-automation.com
 
We mainly supply YOKOGAWA, SIEMENS, EMERSON, ABB, HONEYWELL, Allen Bradley,ENDRESS+ HAUSER, PEPPERL+FUCHS, FESTO, PARKER, FLUKE, WEIDMULLER, MTL, SMC,Schneider, Hirschmann,  ADVANTECH,MOXA, US Sensor, Mean Well, Murphy, YTC. Fisher, Auma, Rittal brands products. 
 
Any brand products inquiry, feel free to contact me.

 
 