description:The MTL5516/C enable two safe-area loads to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the linefault-detect(LFD) facility...
BASIC INFO

MTL5516C 2 Channel Isolation Barrier/SWITCH/ PROXIMITY DETECTOR INTERFACE with NAMUR Input, Relay Output, 10.5 MTL5516C

MTL5516C


1.SPECIFICATIONS for MTL5516/C 

 

The MTL5516/C enable two safe-area loads to be controlled by a switch

or proximity detector located in a hazardous-area. When selected, open

or short circuit conditions in the field wiring are detected by the linefault-detect

(LFD) facility and also indicated on the top of the module.

Phase reversal for each channel is selected by a switch on the side of

the module and output is provided by changeover relay contacts.

 

MTL5516C 2 Channel Isolation Barrier/SWITCH/ PROXIMITY DETECTOR INTERFACE with NAMUR Input, Relay Output, 10.5 MTL5516C

MTL5516C Stock picture
 

Number of channels

Two

Location of switches

Zone 0, IIC, T6 hazardous area

Div. 1, Group A hazardous location

Location of proximity detector

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A hazardous location

Hazardous-area inputs

Inputs conforming to BS EN60947–5–6:2001 standards for

proximity detectors (NAMUR)

Voltage applied to sensor

7 to 9V dc from 1kΩ ±10%

Input/output characteristics

Normal phase

Outputs closed if input > 2.1mA (< 2kΩ in input circuit)

Outputs open if input < 1.2mA (> 10kΩ in input circuit)

Hysteresis: 200µA (650Ω) nominal

Line fault detection (LFD) (when selected)

User-selectable via switches on the side of the unit. Line faults are

indicated by an LED for each channel. The channel output relay is

de-energised if an input line fault is detected.

Open-circuit alarm on if Iin < 50µA

Open-circuit alarm off if Iin > 250µA

Short-circuit alarm on if Rin < 100Ω

Short-circuit alarm off if Rin > 360Ω

Note: Resistors must be fitted when using the LFD facility with a contact input

500Ω to 1kΩ in series with switch

20kΩ to 25kΩ in parallel with switch

Safe-area output

Two single-pole relays with changeover contacts

Note: reactive loads must be adequately suppressed

Relay characteristics

MTL5516C

Response time: 10ms maximum

Contact rating

(Safe Area):

250V ac, 2A, cosØ >0.7,

40V dc, 2A, resistive load

Contact rating

(Zone 2):

35V, 2A, 100VA.

Maximum current consumption

35mA at 24V

Power dissipation within unit

0.84W at 24V
 

MTL5516C 2 Channel Isolation Barrier/SWITCH/ PROXIMITY DETECTOR INTERFACE with NAMUR Input, Relay Output, 10.5 MTL5516C


2. Quality assurance:

1. 100% original product, 100% quality assurance. 
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex and EMS, the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.


3.Contact details:


HONGKONG XIEYUAN TECH CO., LIMITED


Email/Skype:sales5@hkxytech.com/amy@whxyauto.com


Whatsapp/Mobile::+8613135657923
 
Web:www.hkxytech.com/www.plcs-automation.com

 

We mainly supply YOKOGAWA, SIEMENS, EMERSON, ABB, Hesman

ROCKWELL, HONEYWELL, ENDRESS+ HAUSER, PEPPERL+FUCHS, FESTO, PARKER, FLUKE, WEIDMULLER, MTL, SMC,Schneider, Hirschmann, ADVANTECH,MOXA, US Sensor, Mean Well, Murphy, allen Bradley, YTC. Fisher brands products. brand products.
 
Any brand products inquiry, feel free to contact me.

Pre:None Next:MTL5544D REPEATER POWER SUPPLY Single Channel