ABB Contactor NF22E-13 1SBH137001R1322 100-250V50/60HZ-DC Co

description:NF22E-13General InformationExtended Product Type:NF22E-13Product ID:1SBH137001R1322EAN:3471523100138Catalog Description:NF22E-13 100-250V50/60HZ-DC Contactor Relay...
BASIC INFO

ABB Contactor NF22E-13 1SBH137001R1322 100-250V50/60HZ-DC Contactor Relay with good price



1. Product Details:

NF22E-13

General Information

  • Extended Product Type:

NF22E-13

  • Product ID:

1SBH137001R1322

  • EAN:

3471523100138

  • Catalog Description:

NF22E-13 100-250V50/60HZ-DC Contactor Relay

 

 

 

2.Long Description:

 

NF contactor relays are used for switching auxiliary and control circuits. NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. NF contactor relays have built-in surge protection and do not require additional surge suppressors. - Poles: 4-pole contactor relays (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and including the "Mechanically Linked" symbol on the contactor relay side) - Control Circuit: AC or DC operated - Accessories: a wide range of Accessories is available.

 

Categories

  • Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors

Ordering

  • Minimum Order Quantity:

1 piece

  • Customs Tariff Number:

85364900

Popular Downloads

  • Data Sheet, Technical Information:

1SBC101427D0201

  • Instructions and Manuals:

1SBC101027M6801

Dimensions

  • Product Net Width:

45 mm

  • Product Net Depth / Length:

77 mm

  • Product Net Height:

86 mm

  • Product Net Weight:

0.270 kg

Technical

  • Number of Auxiliary Contacts NO:

2

  • Number of Auxiliary Contacts NC:

2

  • Standards:

IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14

  • Rated Operational Voltage:

Auxiliary Circuit 690 V
Main Circuit 690 V

  • Rated Frequency (f):

Auxiliary Circuit 50 / 60 Hz

  • Conventional Free-air Thermal Current (Ith):

acc. to IEC 60947-5-1, q = 40 °C 16 A

  • Rated Operational Current AC-15 (Ie):

(220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A

  • Rated Short-time Withstand Current (Icw):

for 0.1 s 140 A
for 1 s 100 A

  • Maximum Electrical Switching Frequency:

AC-15 1200 cycles per hour
DC-13 900 cycles per hour

  • Rated Operational Current DC-13 (Ie):

(110 V) 0.55 A / 60 W
(220 V) 0.27 A / 60 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(125 V) 0.55 A / 69 W
(24 V) 6 A / 144 W
(250 V) 0.27 A / 68 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W

  • Rated Insulation Voltage (Ui):

acc. to UL/CSA 600 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V

  • Rated Impulse Withstand Voltage (Uimp):

6 kV

  • Maximum Mechanical Switching Frequency:

6000 cycles per hour

  • Rated Control Circuit Voltage (Uc):

50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V

  • Operate Time:

Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms

  • Connecting Capacity Auxiliary Circuit:

Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²

  • Connecting Capacity Control Circuit:

Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²

  • Wire Stripping Length:

Auxiliary Circuit 10 mm
Control Circuit 10 mm

  • Degree of Protection:

acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

  • Terminal Type:

Screw Terminals

Environmental

  • Ambient Air Temperature:

Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air -40 ... +70 °C

  • Climatic Withstand:

Category B according to IEC 60947-1 Annex Q

  • Maximum Operating Altitude Permissible:

3000 m

  • Resistance to Vibrations acc. to IEC 60068-2-6:

5 ... 300 Hz 4 g closed position / 2 g open position

  • Resistance to Shock acc. to IEC 60068-2-27:

Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g

Technical UL/CSA

  • Tightening Torque UL/CSA:

Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb

Certificates and Declarations (Document Number)

 

ABB Contactor NF22E-13 1SBH137001R1322 100-250V50/60HZ-DC Contactor Relay with good price

 
  • ABS Certificate:

ABS_15-GE1349500-PDA_90682247

  • BV Certificate:

BV_2634H24899B0

  • CB Certificate:

CB_SE-89845

  • CCC Certificate:

CCC_2011010303465426

  • cUL Certificate:

UL_20180227_E252354_2_1

  • Declaration of Conformity - CE:

1SBD250005U1000

  • DNV Certificate:

DNV-GL_TAE00001BV

  • DNV GL Certificate:

DNV-GL_TAE00001BV

  • EAC Certificate:

EAC_RU C-FR ME77 B01006

  • Environmental Information:

1SBD250151E1000

  • GOST Certificate:

GOST_POCCFR.ME77.B06804.pdf

  • Instructions and Manuals:

1SBC101027M6801

  • LR Certificate:

LRS_C1400038

  • RINA Certificate:

RINA_ELE084013XG

  • RMRS Certificate:

RMRS_1300132124

  • RoHS Information:

1SBD251014E1000

  • UL Certificate:

UL_20130206-E252354-2-1

  • UL Listing Card:

UL_E252354

Container Information

  • Package Level 1 Units:

1 piece

  • Package Level 1 Width:

87 mm

  • Package Level 1 Depth / Length:

79 mm

  • Package Level 1 Height:

47 mm

  • Package Level 1 Gross Weight:

0.27 kg

  • Package Level 1 EAN:

3471523100138

  • Package Level 2 Units:

54 piece

  • Package Level 2 Width:

250 mm

  • Package Level 2 Depth / Length:

300 mm

  • Package Level 2 Height:

315 mm

  • Package Level 2 Gross Weight:

14.58 kg

  • Package Level 3 Units:

1296 piece

Classifications

  • Object Classification Code:

K

  • E-nummer:

3211448

  • ETIM 4:

EC000196 - Contactor relay

  • ETIM 5:

EC000196 - Contactor relay

  • ETIM 6:

EC000196 - Contactor relay

  • ETIM 7:

EC000196 - Contactor relay

  • UNSPSC:

39121500

ABB Contactor NF22E-13 1SBH137001R1322 100-250V50/60HZ-DC Contactor Relay with good price

 

4. Quality assurance:

 

1. 100% original product, 100% quality assurance. 
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex and EMS, the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.

 


5.Contact details:


HONGKONG XIEYUAN TECH CO., LIMITED


Email/Skype:sales5@hkxytech.com/amy@whxyauto.com


Whatsapp/Mobile::+8613135657923

Web:www.hkxytech.com/www.plcs-automation.com

 

We mainly supply YOKOGAWA, SIEMENS, EMERSON, ABB, HONEYWELL, Allen Bradley,ENDRESS+ HAUSER, PEPPERL+FUCHS, FESTO, PARKER, FLUKE, WEIDMULLER, MTL, SMC,Schneider, Hirschmann, ADVANTECH,MOXA, US Sensor, Mean Well, Murphy, YTC. Fisher, Auma, Rittal brands products. 

Any brand products inquiry, feel free to contact me.


 

Pre:ABB Module FECA-01/FECA-01-KIT EtherCAT Adapter For ACS355, Next:ABB Modular DIN Rail Products/High Performance Circuit Break