plc automation

Hotline

ABB K-TEK Magnetostrictive Level Transmitter AT100

description:This Causes a Torsional Stress Wave to be Induced in the Wire. This Torsion Propagates Along the Wire at a Known Velocity from the Position of the Magnetic Float and Toward Both Ends of the Wire. A Patented Piezo-Magnetic Sensing Element Pla...
BASIC INFO
ABB Magnetostrictive Level Transmitter AT100

ABB AT100 Level Transmitter
1.Overview
This Causes a Torsional Stress Wave to be Induced in the Wire. This Torsion Propagates Along the Wire at a Known Velocity from the Position of the Magnetic Float and Toward Both Ends of the Wire. A Patented Piezo-Magnetic Sensing Element Placed in the Transmitter Assembly Converts the Received Mechanical Torsion into an Electrical Return Pulse. The Microprocessor-Based Electronics Measures the Elapsed Time Between the Start and Return Pulses and Converts it into a 4-20 mA Output, which is Proportional to the Level Being Measured.

2.Features:   
      
§  SIL2 Certified IEC 61508*
§  High Accuracy: .01% of Full Scale
§  Superior Piezo Ceramic Sensor (Patent # 5,473,245)
§  Local Indication with LCD Display
§  Never Requires Re-Calibration: Set It & Forget It
§  Dual Compartment Housing with Separate Field Terminal Compartment
§  Loop Powered to 75’ (22M) Probe Length
§  Total and/or Interface Level Measurement
§  Pressure to 3000psig (207 bar), Std. 1800 psig (124.1 bar)
§  Temperature Range: -320 to 800º F (-196 to 427ºC) with options
§  Field Replaceable / Upgradable Electronics Module
§  Built In RFI / EMI Filter
§  Digital Communications

3.OPTIONS:
§  Two Level Indications
§  Temperature Indications
§  Foundation Fieldbus Output
§  Honeywell DE Output
§  Glass Viewing Window
§  316L Stainless Steel Enclosure
20 Point Strapping Table

4. Ordering Informations:
 

ABB Magnetostrictive Level Transmitter AT100

AT100/a/b/c/d/e/f/g/h/I/j/k:
Example: AT100/S6/LW/A/R1/H0/M4A/X/FM/CF/F1B/48”
/a Probe Material
S6 316L Stainless Steel Standard
A2 Alloy 20
HC Hastelloy C-276 (1/2” OD SW1 Probe without Sensor Well)
TF PFA Jacket (1/16” thick) over 316L SS (Max 350ºF (177ºC) & 50 psig (3.4bar))
/b Transmitter Configuration
L Standard Local Transmitter
LW Standard Local Transmitter with Window Cover
T Local Transmitter with Top Access or Readout
TW Local Transmitter with Top Access or Readout and Window Cover
C Offset Transmitter with Vapor Seal for Service Below Ambient
CW Offset Transmitter with Vapor Seal for Service Below Ambient and Window Cover
/c Transmitter Housing
A Standard Dual Compartment Aluminum Housing
S Dual Compartment 316L Stainless Steel Housing
/d Probe Type
R1 Standard Rigid Probe, 5/8” OD
Notes: 1. 30 ft. (9.14m) maximum probe length
2. 1400 psig ( 96.5bar) @ 800ºF (427ºC)
3. 1600 psig (110.3bar) @ 700ºF (371ºC)
4. 1800 psig (124.1bar) @ 300ºF (149ºC)
F1 Flexible Teflon® (a registered trademark of DuPont) Sensor Inserted into 1” OD Segmented
Sensor Well
Notes: 1. Only available with /S6, /A2, /HC options.
2. 75 ft. (22.86 m) maximum probe length.
3. 300 psig (20.7bar) maximum & 170ºF (77°C) maximum.
4. Specify maximum segment length, 10ft. (3.05m) standard.
5. Not suitable for explosion proof service.
6. Suitable for intrinsically safe installation.
7. Not suitable for cryogenic applications.
HP High Pressure Rigid Probe, 5/8” OD
Notes: 1. Not available with /TF probe material option.
2. 30 ft. (9.14m) maximum probe length.
3. 3000 psig (206.8 bar) maximum.
4. Not available with /H3 Process Temperature Option.
SW1 1/2” OD Rigid Probe for Insertion Into 5/8” OD x 0.049” Wall Sensor Well
Notes: 1. Specify and order sensor well separately.
2. 20 ft. (6.10m) maximum probe length.
3. Not available with /H3 Process Temperature Option.
SW2 5/8” OD Rigid Probe for Insertion Into 3/4” Sch. 40 or 80 Sensor Well
Notes: 1. Specify and order sensor well separately.
2. 30 ft. (9.14m) maximum probe length.
SW3 1/2” OD Flexible Probe for Insertion Into 5/8” OD x 0.49” wall Sensor Well
Notes: 1. Max 300ºF (149ºC) @ 1 hour Clean.
2. 15 ft. (4.57m) maximum probe length.
3. Available with /S6 probe material only.
4. Not suitable for explosion proof service.
5. Probe is not hermetically sealed. For use in conditioned (non-condensing) indoor locations only.
6. Only available with H0 process temperature option.
/e Process Temperature Options
H0 < 170ºF (77ºC) Maximum; Top of transmitter is 8” (200mm) above process connection
H1 < 250ºF (121ºC) Maximum; Top of transmitter is 16” (406mm) above process connection
H2 < 450ºF (232ºC) Maximum; Top of transmitter is 26” (660mm) above process connection
H3 < 800ºF (427ºC) Maximum; Top of transmitter is 26” (660 mm) above process connection
Note: 15 ft. (4.57m) maximum probe length.
 
ABB Magnetostrictive Level Transmitter AT100

5. ORDERING INFORMATION (continued)
 
/f Electronic Module
X None
HART Protocol: M4A One Level, LCD Indicator & SIL 2 rated 4-20 mA Output
M4B Two Levels, LCD Indicator & SIL 2 rated 4-20 mA Output
M4AS One Level, LCD Indicator & SIL 2 rated 4-20 mA Output & 20 point Strapping Table
M4BS Two Levels, LCD Indicator & SIL 2 rated 4-20 mA Output & 20 point Strapping Table
M5A One Level, One temperature point, LCD indicator, and Communications
M5B Two Levels, One temperature point, LCD indicator, and Communications
Foundation
Fieldbus Protocol:
M4AF One Level & LCD Indicator
M4BF Two Levels & LCD Indicator
M4AFS One Level & LCD Indicator & 20 point Strapping Table
M4BFS One Level & LCD Indicator & 20 point Strapping Table
Honeywell
DE
Protocol:
M4AD One Level & LCD Indicator
M4BD Two Levels & LCD Indicator
/g Second Analog Output (Not SIL Rated)
X None
RI Second electronic module with 1 ea. Analog output and LCD indication
Notes: 1. Only for use with HART Protocol equipped electronics modules
2. The RI100 is only approved as an Explosion Proof device
3. Analog output field selectable to any of the two levels or temperature
4. Housing type will be same as primary transmitter housing (/c above)
/h Approvals1,2
FM Factory Mutual
CSA Canadian Standards Association
CEX ATEX Flameproof
CEI ATEX I.S.
IEI International Electromechanical Commission I.S.
IEX International Electromechanical Commission Flameproof
GR GOST Russia
Notes: 1. All Explosion Proof Approvals exclude Probe F1 and SW3.
2. All Intrinsically Safe Approvals exclude RI (secondary analog output) & Honeywell DE options.
/i Process Connection
X None (use with /SW1, /SW2 and /SW3 probe types)
CF Standard adjustable compression fitting 3/4” MNPT (1”MNPT with /F1 probe type)
FL Flange or plug (shipped loose) with FNPT thread for use with compression fitting
(specify type, material and rating from SLG-0001-1 Flange Designation Chart)
WP Flange or Plug welded to the sensor tube without compression fitting
(specify type, material and rating from SLG-0001-1 Flange Designation Chart)
/j Float Type
X None (Use this selection with /SW1, /SW2, & /SW3 probe types)
Fnn Selection from Standard Float Chart (SLG-0003-1) or specify /FXX for custom float
/k Insertion Length
L Specify inserted length from process connection to end of probe in inches or millimeters or meters
Consult factory for ML, L1 & L2. There is an unusable range of 2.5 inches minimum (12” for /F1) at the bottom of the
sensing tube (which can be reduced depending upon float dimensions).
The unusable range at the top of the sensor tube will be affected by the float dimensions.
NOTE: Consult factory for special application requirements.
 
Available Accessories:
M20 ISO FITTING: M20 Female Electrical Connection (MM - Brass or MMS - Stainless Steel)
For fastest response to inquiries provide a completed AT100 Application Data Sheet of the Serial Number of an existing AT100.

5. Quality assurance:

1. 100% original product, 100% quality assurance. 
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex and EMS, the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 

6.Contact details:
 
HONGKONG XIEYUAN TECH CO., LIMITED  
 
Email:amy@whxyauto.com
 
Whatsapp::+8613135657923 
 
Skype:amy@whxyauto.com 
 
Mobile :+86 13135657923 
 
Website:www.plcs-automation.com
Pre:None Next:ABB FEP311 Series PROCESSMASTER FLOW METER FEP311025A1S1D4B1